Thermo Scientific™

DNAPac™ PA100 Oligonucleotide HPLC Columns

Catalog number: 043011
Thermo Scientific™

DNAPac™ PA100 Oligonucleotide HPLC Columns

Catalog number: 043011

Feature strong anion-exchange resin for high-resolution analysis and purification of synthetic and modified oligonucleotides with Thermo Scientific™ Dionex™ DNAPac™ PA100 Oligonucleotide Columns.

 
Catalog Number
043011
Unit Size
Each
Particle Size
13 μm
Diameter (Metric)
9 mm
Length (Metric)
250 mm
Price (USD)
Price: 3,156.57
Your price:
Full specifications
Quantity
Column FormatAnalytical Column
Diameter (Metric)9 mm
Flow Rate1 mL/min
For Use WithASRS, DX-500 BioLC Chromatography System
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, acetate, or bromide in lithium, sodium or ammonium forms
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TypeAnalytical Column
TechniqueBio-LC
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
13 μm
Diameter (Metric)
4 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,583.62
Your price:
Full specifications
Quantity
Column FormatAnalytical Column
Diameter (Metric)4 mm
Flow Rate1 mL/min
For Use WithASRS, DX-500 BioLC Chromatography System
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, acetate, or bromide in lithium, sodium or ammonium forms
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TypeAnalytical Column
TechniqueBio-LC
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
13 μm
Diameter (Metric)
2 mm
Length (Metric)
50 mm
Price (USD)
Price: 1,001.62
Your price:
Full specifications
Quantity
Column FormatGuard Column
Diameter (Metric)2 mm
For Use WithASRS, DX-500 BioLC Chromatography System
Length (Metric)50 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Column TypeIon Exchange
TypeGuard Column
TechniqueNucleic Acid/Anion Exchange
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
13 μm
Diameter (Metric)
4 mm
Length (Metric)
50 mm
Price (USD)
Price: 765.73
Your price:
Full specifications
Quantity
Column FormatGuard Column
Diameter (Metric)4 mm
For Use WithASRS, DX-500 BioLC Chromatography System
Length (Metric)50 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialPolymeric Resin
Column TypeIon Exchange
PhaseIon Exchange
TypeGuard Column
TechniqueBio-LC
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
13 μm
Diameter (Metric)
2 mm
Length (Metric)
250 mm
Price (USD)
Price: 2,815.19
Your price:
Full specifications
Quantity
Column FormatAnalytical Column
Diameter (Metric)2 mm
Flow Rate1.5 mL/min
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialNonporous, Polymeric Resin
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
13 μm
Diameter (Metric)
22 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Quantity
-
Column FormatPreparative Column, Standard
Diameter (Metric)22 mm
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
13 μm
Diameter (Metric)
9 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Quantity
-
Column FormatPreparative Column, Standard
Diameter (Metric)9 mm
Flow Rate1.5 mL/min
Length (Metric)50 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
13 μm
Diameter (Metric)
22 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Quantity
-
Column FormatPreparative Column, Standard
Diameter (Metric)22 mm
Length (Metric)50 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
Showing 8 of 8
Catalog NumberSpecificationsUnit SizeParticle SizeDiameter (Metric)Length (Metric)Price (USD)Quantity
043011Full specifications
Each13 μm9 mm250 mm
Price: 3,156.57
Your price:
Column FormatAnalytical Column
Diameter (Metric)9 mm
Flow Rate1 mL/min
For Use WithASRS, DX-500 BioLC Chromatography System
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, acetate, or bromide in lithium, sodium or ammonium forms
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TypeAnalytical Column
TechniqueBio-LC
Unit SizeEach
043010Full specifications
Each13 μm4 mm250 mm
Price: 1,583.62
Your price:
Column FormatAnalytical Column
Diameter (Metric)4 mm
Flow Rate1 mL/min
For Use WithASRS, DX-500 BioLC Chromatography System
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, acetate, or bromide in lithium, sodium or ammonium forms
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TypeAnalytical Column
TechniqueBio-LC
Unit SizeEach
088761Full specifications
Each13 μm2 mm50 mm
Price: 1,001.62
Your price:
Column FormatGuard Column
Diameter (Metric)2 mm
For Use WithASRS, DX-500 BioLC Chromatography System
Length (Metric)50 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Column TypeIon Exchange
TypeGuard Column
TechniqueNucleic Acid/Anion Exchange
Unit SizeEach
043018Full specifications
Each13 μm4 mm50 mm
Price: 765.73
Your price:
Column FormatGuard Column
Diameter (Metric)4 mm
For Use WithASRS, DX-500 BioLC Chromatography System
Length (Metric)50 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialPolymeric Resin
Column TypeIon Exchange
PhaseIon Exchange
TypeGuard Column
TechniqueBio-LC
Unit SizeEach
088760Full specifications
Each13 μm2 mm250 mm
Price: 2,815.19
Your price:
Column FormatAnalytical Column
Diameter (Metric)2 mm
Flow Rate1.5 mL/min
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialNonporous, Polymeric Resin
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
088759Full specifications
Each13 μm22 mm250 mmRequest A Quote-
Column FormatPreparative Column, Standard
Diameter (Metric)22 mm
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
088764Full specifications
Each13 μm9 mm50 mmRequest A Quote-
Column FormatPreparative Column, Standard
Diameter (Metric)9 mm
Flow Rate1.5 mL/min
Length (Metric)50 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
088765Full specifications
Each13 μm22 mm50 mmRequest A Quote-
Column FormatPreparative Column, Standard
Diameter (Metric)22 mm
Length (Metric)50 mm
Max. Pressure4000 psi (275 bar)
Particle Size13 μm
pH2 to 12.5
Pore SizeNonporous
Temperature90°C
Stationary PhaseQuaternary Ammonium
Product LineDNAPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
Showing 8 of 8
  • 13μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads™
  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text